1 HP Windows Mixed Reality Headset is not for children under the age of 13. All users should read the HP Windows Mixed Reality Headset User Guide to reduce the risk of personal injury, discomfort, property damage, and other potential hazards and for important information related to your health and safety when using the headset.
Windows Mixed Reality requires Windows 10 Fall Creator’s Update. Features may require software or other 3rd party applications to provide the described functionality.
I'm having issues getting Hyper-V RC to run on a new HP DL-320 G5 Server with a single Xeon 3050 processor and Windows 2008 Standard Edition x64. Issue in a new HP Proliant ML350 G5 Server with a single Xeon E5310 and Windows 2008 Enterprise Edition. And the Intel VT is enabled in the BIOS. CRITICAL ** Systems ROMPaq Firmware Upgrade for HP ProLiant ML310 G5/DL320 G5p (W05) Servers. By downloading, you agree to the terms and conditions of the Hewlett Packard Enterprise Software License Agreement. Note: Some software requires a valid warranty, current Hewlett Packard Enterprise support.
To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value: a7a1310834aa6d3b19bbb63abfe08aba SP39959.exe Installation: This Enhanced SoftPaq contains utilities that can be used to restore and/or update the system ROM on the HP ProLiant Server. Download the Enhanced SoftPaq to a directory on a system running Microsoft Windows 2000, Microsoft Windows Server 2003, Microsoft Windows Server 2008, Microsoft Windows XP, or Microsoft Windows Vista and change to that directory. From that drive and directory, execute the downloaded Enhanced SoftPaq file simply by double clicking on the SPxxxxx file and follow the installation wizard to complete the Enhanced SoftPaq installation process. Acronis True Image Hd Download Iso. At the end of a successful installation of the Enhanced SoftPaq, a web page will automatically appear to provide you with the different methods for restoring and/or upgrading the firmware on the system.
End User License Agreements: Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version. Important: This Enhanced SoftPaq version contains new functionality that provides additional firmware upgrade options to the user. Please review the user documentation contained within this Enhanced SoftPaq to learn more about these new features.
All files contained within and created by this Enhanced SoftPaq are specific to this ProLiant Server. Files are not interchangeable with other ProLiant Server Families. Resolved an issue with Western Digital 80GB SATA Hard Drives where the System ROM would report a SMART drive error and hang while trying to boot the drive. Resolved an issue where under rare circumstances a system may hang during POST if the system battery loses power or is removed. Updated system thermals to avoid a POST temperature violation. This will avoid the '1610-Temperature violation detected' message from appearing under certain system configurations with higher ambient temperatures. Resolved an issue where disabling one of the embedded NICs in the ROM-Based Setup Utility (RBSU) did not actually prevent the operating system from seeing the NIC.
The NIC would still show up under the operating system but would not have any resources assigned. The embedded NICs on this platform cannot be disabled individually. RBSU will no longer allow disabling the embedded NICs.
Resolved various USB issues. This includes addressing an issue with Legacy USB boot support where the system would sometimes not detect a USB CD ROM and fail to boot the media. Also correct an issue with USB One Button Disaster Recovery (OBDR) tape drive support.
Resolved an issue where legacy USB support would not work when iLO Firmware version 1.20 or earlier was installed on the system. Resolved an issue where the embedded fan solution was not properly reporting the default fan speeds through remote diagnostic utilities. Resolved an issue where the embedded PXE ROM would fail to run during POST when multiple Option ROMs are first run from expansion (plug-in) cards.
Resolved an issue where the ROM Based Setup Utility (RBSU) would fail to set the Boot Controller Order properly when multiple SmartArray controllers were installed. This failure would manifest itself by the System ROM booting from the wrong storage controller. To ensure the integrity of your download, HP recommends verifying your results with this MD5 Checksum value: a7a1310834aa6d3b19bbb63abfe08aba SP39959.exe Installation: This Enhanced SoftPaq contains utilities that can be used to restore and/or update the system ROM on the HP ProLiant Server. Download the Enhanced SoftPaq to a directory on a system running Microsoft Windows 2000, Microsoft Windows Server 2003, Microsoft Windows Server 2008, Microsoft Windows XP, or Microsoft Windows Vista and change to that directory. From that drive and directory, execute the downloaded Enhanced SoftPaq file simply by double clicking on the SPxxxxx file and follow the installation wizard to complete the Enhanced SoftPaq installation process.
At the end of a successful installation of the Enhanced SoftPaq, a web page will automatically appear to provide you with the different methods for restoring and/or upgrading the firmware on the system. Release Notes.
End User License Agreements: Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version. Important: This Enhanced SoftPaq version contains new functionality that provides additional firmware upgrade options to the user. Please review the user documentation contained within this Enhanced SoftPaq to learn more about these new features. All files contained within and created by this Enhanced SoftPaq are specific to this ProLiant Server. Files are not interchangeable with other ProLiant Server Families. Upgrade Requirement: Optional - Users should update to this version if their system is affected by one of the documented fixes or if there is a desire to utilize any of the enhanced functionality provided by this version. Added support for Generation 2 (3.0 Gb/s) SATA Hard Drives.
This revision of the System ROM is required for proper operation of the embedded SATA solution when a Generation 2 (3.0 Gb/s) SATA hard drive is installed in the server (DL320 G5 only). Version:2008.04.10 (A) (28 Apr 2008).
Resolved an issue with Western Digital 80GB SATA Hard Drives where the System ROM would report a SMART drive error and hang while trying to boot the drive. Resolved an issue where under rare circumstances a system may hang during POST if the system battery loses power or is removed. Updated system thermals to avoid a POST temperature violation. This will avoid the '1610-Temperature violation detected' message from appearing under certain system configurations with higher ambient temperatures. Resolved an issue where disabling one of the embedded NICs in the ROM-Based Setup Utility (RBSU) did not actually prevent the operating system from seeing the NIC.
The NIC would still show up under the operating system but would not have any resources assigned. The embedded NICs on this platform cannot be disabled individually. RBSU will no longer allow disabling the embedded NICs. Resolved various USB issues. Driver Gadmei Utv 330 Windows Xp on this page. This includes addressing an issue with Legacy USB boot support where the system would sometimes not detect a USB CD ROM and fail to boot the media.
Also correct an issue with USB One Button Disaster Recovery (OBDR) tape drive support. Resolved an issue where legacy USB support would not work when iLO Firmware version 1.20 or earlier was installed on the system. Resolved an issue where the embedded fan solution was not properly reporting the default fan speeds through remote diagnostic utilities. Resolved an issue where the embedded PXE ROM would fail to run during POST when multiple Option ROMs are first run from expansion (plug-in) cards. Resolved an issue where the ROM Based Setup Utility (RBSU) would fail to set the Boot Controller Order properly when multiple SmartArray controllers were installed. This failure would manifest itself by the System ROM booting from the wrong storage controller.
Added latest product names of optional expansion cards for display in RBSU. Added support for latest Intel XEON processors. Added support for 16 Standard Boot (IPL) devices. This feature will allow users to configure the IPL boot order from the ROM Based Setup Utility (RBSU) for additional devices in the system.
Note - Any system that currently has more than 8 IPL devices will have the Standard Boot Order (IPL) reset back to factory defaults after flashing the System ROM. Version:2006.08.25A (9 Oct 2006).